Stop beating arround the bush!

We need action and progress!
No diluting and digressing!



This telegraph article on "The low-cost family house of the future" is a prime example of the hot air our society and precisely lobbies of all kinds of industries are producing, obviously trying to avoid progress threatening established margins by all means.

The article is all about low-cost and low-energy but it avoids the slightest, in fact any reference to real numbers; as such those terms remain as accurate as the coordinates of cloud-cuckoo-land, obviously just another exercise to fill the paper and irritating the public.

Cost in relation to home building regularly comes as £ per square metre [£/m²] and low-energy refers to gobbledygook unless you define the energy consumption; internationally that is done in kiloWatt per square metre and year [kW/m²a].

There is, oh wonder oh Telegraph, an international Standard, supra-nationally now accepted in many countries, from Japan to the US, from Norway to South Africa, in Australia and in South America: it is called Passive House Standard; it defines the maximum energy consumption to be no more than 15 kW/m²a* for the space heating demand. To get there it needs a thorough calculation taking many different factors into account not only the construction's location and orientation but also all materials', all components' and all appliances' energy efficiencies; the software developed to do exactly that is called PHPP, the Passive House Planning Package.

Solar gain and lunar loss, air-changes per hour [ach], air tightness, U-values, thermal conductivity, thermal bridging, psi-values, efficiency values those are the modern parameters to take into account. Quite a difference to living in caves or cavity-cold homes.
 
So it is time to stop producing hot air, time to end this useless inventing British complicated but diluted standards that no enduser will be able to understand (> CoSH); no need to invent any more British wheels again and again; what is needed is for all members of the British construction industry, from the bosses down, to (want to) understand that it is high time to apply this existing and proven knowledge extensively, now!

It would also end rubbish like ...

There were also technical issues for the Simonsens. The ventilation system broke down on a Friday night, and an engineer had to be called out to fix the problem. The technology in the Kettering house is similarly daunting with a plant room filled with pipes and tanks. Nik says if it goes wrong: “I have a number to call.”

What shall sound so dangerous describing a dramatic high-tech problem like The ventilation system broke down... can be no more than one ventilator that probably had no more power supplied and that similarly daunting with a plant room filled with pipes and tanks by implication just avoids the dirty chaos in British homes with pipes and pumps, tanks and meters dumped into dark and poky cupboards, an almost inaccessible attic or into so desperate needed bathroom or kitchen cabinets guaranteed avoiding proper access for maintenance or repair.

And cost? From experience it can be done for around £1,500 per square metre, Passive House Standard, turnkey - now, to compare like with like one should know what turnkey really comprises! And make sure that both products, turnkey homes, built to PH Standard, hence comparable in energy consumption! Plus, make sure that both homes are heated to the same levels, i.e. 21° in all rooms, but 19°C in the bedrooms. I know, complicated, but I said like with like! And efficiency does not come with throwing the dice!

Here is one pretty good wall... (not a PH wall) but a wall is just one element of the complex calculation, anyway.




Carpe diem!

* one litre of heating oil equates to 10.7kW, so your 150m² 5-bedroom house should not use more than the equivalent energy of 210 litres of heating oil per year or roughly £13 a month to keep a temperature of 21°C throughout the house (bedrooms 19°C). Now you compare!



Monday, 16 August 2010

draught-tight or air-proofing...

or is it vice versa?

I am sure our forefathers already tried to find that draught-proof cave...

The other day I was left with the following tweet line:

...(I) prefer draught proofing for general public & getting them to understand concept, couldn't sell ' air flow control'.

I had initially provoked the line when I had criticised the terminology "draught-proofing" as being not good and precise enough in comparison to the term "air tightness" or rather "air flow control". My intention had not been to offend the addressee, an architect, but to make clear that modern construction need to be built to a precise standard, for example to meet a given standard of air-tightness level.

Why?

Well, the air we breathe among others transports water (humidity) and thermal energy (heat/cold), but also all sorts of dirt, dust, germs and spore. So to set a level for the air exchange rate helps to control the levels of what it contains; many reasons speak for an air tight building envelope:
  • it avoids structural damage
  • ... draughts
  • ... and energy losses;
  • it improves noise protection within the building and to/from the outside
  • ... and air quality.
Of course, the tighter your envelope becomes the more ventilation is a must; the best solution is to install a controlled automated ventilation system including thermal energy recovery (heat/cold), something that we had installed in our first house in 1981 and love ever since.

I think even the "general public" ought to know and understand these principles as I am a firm believer in customers that not only know what they want but understand why they want it. Ignorance may help to close a clever deal for one side but will turn out to be a bad advisor for both.

The technology exists; what is needed is the understanding and education of both, the industry and the customer accompanied by the will of both to make a difference. Once that happens health and comfort will replace the discussions about morbid homes and heating allowances.

A win-win situation as it will be the time when "Affordables" become affordable.